Following the Evidence Enteral Tube Feedings Infant
Authors
- Clifford, Patricia MSN, RNC-NIC
- Heimall, Lauren MSN, PCNS-BC
- Brittingham, Lori MSN, CNS-ACCNS-N
- Finn Davis, Katherine PhD, RN
Abstract
Enteral tube placement in hospitalized neonates and young children is a common occurrence. Accurate placement and verification are imperative for patient safety. However, despite many years of research that provides evidence for a select few methods and clearly discredits the safety of others, significant variation in clinical practice is still common. Universal adoption and implementation of evidence-based practices for enteral tube placement and verification are necessary to ensure consistency and safety of all patients. This integrative review synthesizes current and seminal literature regarding the most accurate enteral tube placement and verification methods and proposes clinical practice recommendations.
Article Content
Enteral tubes are commonly used in hospitalized neonates and pediatric patients as a means to deliver nutrition and medication by the naso- or orogastric route. Safe and effective use of these tubes is achieved by ensuring correct placement and appropriately verifying location before each use. Despite evidence to guide nursing practice in the placement and verification of enteral tubes, outdated and unsafe practices are common. Multiple authors reported that significant variations exist for verification of enteral tube placement.1-3 A recent prevalence study, which included more than 60 pediatric hospitals, found the verification method most commonly used was aspiration with inspection, followed by auscultation, assessing measurement markings, gastric pH, and x-ray studies.3
Optimal positioning of enteral tubes is within the body of the stomach, below the esophageal junction. Depending on the definition of malposition, error rates range from 21% to 56%.4-7 Errors in initial placement, and those related to displacements that occur over time, can lead to deleterious consequences and result in serious patient harm. Enteral tubes located in the esophagus, or placed inadvertently in the lungs, can lead to apnea, bradycardia, desaturations, and aspiration. Tubes placed unintentionally near the pyloric junction and in the duodenum can cause malabsorption, diarrhea, dumping syndrome, and inadequate weight gain. Several published case studies have revealed incidents of perforations of the esophagus and the stomach by misplaced enteral tubes, especially in low-birth-weight infants.8,9
Although methods of predicting enteral tube insertion length and verifying position following placement have been widely explored in the literature, standardized methods have not been widely adopted. This integrative review synthesizes current and seminal literature regarding the most accurate enteral tube placement and verification methods in neonatal and pediatric patients and makes recommendations for clinical practice.
METHODS
Information sources
An initial literature search was conducted between May and August 2014, using the electronic databases of the Cumulative Index to Nursing and Allied Health Literature (CINAHL), MEDLINE, and PubMed, for studies published between January 2009 and June 2014. Only articles written in English were considered. Search terms included the following: nasogastric, orogastric, enteral tube, gastric tube, feeding tube, and premature and were limited by patient age of 0 to 18 years. In addition to the literature, national enteral tube guidelines, practice alerts, and neonatal guidelines were reviewed. Reference lists from literature in our initial search yielded seminal articles back to 1993 that were deemed important to include.
Critical appraisal of articles
The expanded literature search yielded 56 pediatric and adult articles and 7 national guidelines dating from 1993 to 2014. We further examined only the articles and guidelines that met our inclusion criteria of specifically addressing gastric enteral tube placement and verification methods. We excluded articles that did not directly involve or were not applicable to neonates and/or young children. After identifying the 28 articles appropriate for inclusion, the literature was critiqued using the Johns Hopkins Nursing evidence appraisal system.10 Each article was independently reviewed by one of the authors. Any disagreements regarding the critiques were resolved by a subset of authors who reviewed the article in question and reached agreement. The strength of evidence ranged from level I (highest) to level V (lowest). Two of the articles were randomized controlled trials (level I) and the remaining articles were quasi-experimental (level II), nonexperimental (level III), clinical practice guidelines (level IV), or literature reviews and expert opinions (level V). Quality-of-evidence ratings of A (high), B (good), and C (low/major flaw) were also assigned (see Table 1).
| Table 1-a. Table of evidence for methods of enteral tube placement and verification in neonates and young children. |
FINDINGS
Placement of tubes
Several methods exist for determining the appropriate insertion length when placing an enteral tube. The NEX method measures the enteral tube length from the nares to the ear and then to the xiphoid (NEX) process. Although used for many years, this method has not been validated in the literature and multiple studies have demonstrated that tubes placed using this method are often malpositioned, most frequently in the esophagus.5,12,14,16 For the age-related height-based (ARHB) method, heights in age groups are used to determine tube depth placement. This method requires potentially time-consuming and error-prone mathematical calculations and, although successful in adults and children, has been minimally studied only in the neonatal population.5,12
Minimal insertion length has been studied as a means to ensure gastric tube placement in infants weighing less than 1500 g.19 In addition, Freeman and colleagues18 proposed a weight-based formula for estimating enteral tube insertion length in infants. These methods may be useful in improving the accuracy of tube placement, especially when combined together with other methods. However, both studies demonstrated limitations and these methods require further investigation and validation.
The currently recommended practice is the NEMU method, which measures from the nares to the ear, to the distance halfway between the xiphoid process and the umbilicus, referred to as the mid-umbilicus area. This method has demonstrated consistent placement of enteral tube portholes within the body of the stomach.12,28,30 The location of tube portholes varies on the basis of the manufacturer. Ensuring gastric placement of all portholes is necessary to avoid the risk of complications that may result from misplacement. National guidelines, including those set by the American Academy of Pediatrics Neonatal Resuscitation Program33 and the National Association of Neonatal Nurses,34 currently recommend the NEMU placement method (see Figure 1).
| Figure 1. NEMU points of measurement. Printed with permission from The Children's Hospital of Philadelphia. NEMU indicates nose-ear-mid-xiphoid-umbilicus. Printed with permission from The Children's Hospital of Philadelphia. |
Tube placement verification methods
Verification of correct tube placement prior to each use is imperative. Currently, only one method, x-ray study, provides 100% accuracy in determining enteral tube tip location4,11,14,18,22 and is considered the criterion standard by which to compare other verification methods.31,35 A variety of other methods have been studied, but none afford the conclusive findings that an x-ray study provides. Patients receive a minimal amount of radiation from single x-ray exposure; however, the potential cumulative effect from multiple x-ray exposures for enteral tube verification may cause harm. Therefore, other methods of verification are important to consider for patients with long-term, indwelling enteral tubes.
Multiple methods exist for verification of enteral tube placement. Determining the pH of tube aspirate is one method. Adequate pH measurement requires the use of pH paper with a scale range of 1 to 10, as a larger range does not provide the sensitivity needed. The American Association of Critical-Care Nurses11 recommends an x-ray study for initial enteral tube placement verification and pH measurements of 5 or less for subsequent placement verification. The pH of the gastrointestinal tract varies depending upon location. Gastric contents usually have a pH of 1 to 4 and most often 5 or less.21,23 An enteral tube aspirate pH of 6 or greater usually indicates intestinal placement, but pulmonary and esophageal aspirates may also yield a high pH.14 The esophageal aspirate of a patient with reflux may demonstrate a low pH if gastric acid refluxes up to the tip of a tube placed proximal to the stomach. Determining pH can be difficult if insufficient gastric aspirate is obtained for testing. Lack of gastric fluid may be caused by decreased gastric motility or may indicate gastric tube misplacement. A study by Ellett and colleagues14 demonstrated an ability to aspirate fluid for pH testing in approximately 94% of subjects.
Feedings and medications may alter gastric pH. Most infant formulas have a pH of approximately 6.6, and when mixed with gastric secretions, can raise pH measurements of aspirates,22 although the difference is not statistically significant.23 The pH of breast milk ranges from 7.0 to 7.4, depending on the age of the infant.36 Fasting neonates have a mean pH of 4.3.23 The use of H2-blocking agents has raised concern regarding the accuracy of pH testing. Aspirates of patients receiving H2 blockers demonstrated only slightly higher pH levels than the aspirates of subjects who did not receive H2-blocking medication, and the pH remained 5 or less.31 Ellett and colleagues14,17 compared the gastric pH values of children receiving acid-blocking medications with those of children not receiving such medications. The authors found no significant difference in the pH aspirate between the 2 groups and also found that the feeding method-fasting, bolus, intermittent, or continuous-did not alter the mean pH.
Appearance of gastric aspirate is often used in addition to assessing the pH method for determining tube placement. Aspirate color is most helpful in determining if the tube is located in the stomach or intestine (see Table 2). Intestinal aspirates are usually green due to the presence of bile. Clear, tan, or off-white aspirate may indicate gastric or tracheobronchial secretions. Secretions from the pleural space are usually pale white or yellow, similar to the color of gastric secretions.24,29 Aspirate color may vary, depending on the timing of the sampling in relation to the last feeding. Flushing an enteral tube with water may yield a clear fluid, which could indicate a gastric or tracheobronchial aspirate.
| Table 2. Aspirate color table |
Assessment of respiratory distress at the time of placement may or may not indicate that an enteral tube has entered the respiratory tract. Respiratory placement of enteral tubes is rare in the pediatric population14,17; however, misplacement must be ruled out because of the devastating consequences. Placement of small-bore tubes, such as those used in neonatal and pediatric patients, often produces no respiratory distress if misplaced. Patients who are severely debilitated or unconscious often fail to elicit any sign of respiratory distress when tubes are placed in the respiratory tract.
Marking the exterior of the tube at the time of measurement and placing that marking at the lip or nares is a common practice. Checking that the marking has not moved does not indicate that an initially properly placed tube has not migrated or coiled, thus changing the position of the tube and rendering it unsafe for use. This method should only be used in addition to other more reliable methods.1,11
The auscultation method for tube placement verification involves air insufflation into the enteral tube while a nurse listens for the "swoosh" sound of air entering the stomach. This method has repeatedly proven unreliable, as it is impossible to distinguish with great certainty if air sounds are originating from the abdomen, lung, or esophageal region.11,14,19,26,27,35 In 2012, the Child Health Patient Safety Organization25 recommended the discontinuation of auscultation as a method for enteral tube placement verification due to the high incidence of misplaced tubes associated with this method.
Tube placement verification with suboptimal evidence
Testing enteral tube aspirate for bilirubin and gastric enzymes has also been studied. Both of these tests help differentiate if an enteral tube is gastric or postpyloric.32 Aspirates that test positive for bilirubin should indicate that the enteral tube is postpyloric. However, a study performed by Ellett and colleagues17 found that some aspirate samples containing bilirubin were obtained from an enteral tube that was gastric on radiographs rather than the expected postpyloric placement. Testing for gastric enzymes pepsin and trypsin is accurate in determining gastric placement,32 but these tests are performed in a laboratory, not at the bedside, thus decreasing feasibility.
Capnography and capnometry use carbon dioxide (CO2) detection to determine enteral tube location. Capnography detects a CO2 waveform emitted from an enteral tube and can indicate misplacement in the respiratory tract. Monitoring occurs as the tube is placed, first in the midesophagus. Absence of a CO2 waveform allows the nurse to assume that the tube is not in the respiratory tract and the tube can then be advanced to the appropriate centimeter marking for gastric placement.13,15 Capnography has not been adequately studied in the neonatal and pediatric populations. Capnometry uses an end-tidal CO2-detecting device attached to the end of an enteral tube. Color change indicates the presence of CO2, hence placement in the respiratory tract. Researchers have demonstrated success in using capnometry in infant and pediatric studies.20 As with capnography, capnometry does not determine correct placement in the stomach since the tube can be located anywhere along the gastrointestinal tract.
LIMITATIONS
This integrative review has a few limitations. The major limitation is the lack of purely neonatal evidence. We included all neonatal literature that is appropriate and available. Most of the literature includes a large age range, from neonates up to and including adults. In addition, the studies we do have are mostly lower levels of research.
DISCUSSION
Evidence-based methods of placement and verification of enteral tubes should be the cornerstone of nursing practice. However, significant variation exists for both practices.31 Research demonstrates that placement of enteral tubes using the NEX method accounts for up to 21% of tubes being malpositioned.14 Use of the NEX method allows for the highest risk for misplacement and aspiration among the methods reviewed. National organizations and safety groups have emphatically stated that the NEX method should not be used.11,25,26,28,34 The NEMU method is the safest and most accurate method for placement in neonates and young children. A study with neonates by Ellett and colleagues5 indicate that both the ARHB and NEMU methods have an accuracy of 100% and 92%, respectively, for placement in the stomach, duodenum, or pylorus region. There was no statistical difference for correctly placed tubes in the stomach using the ARHB (78%) or NEMU (91%) method. Research in children older than 1 month also showed that the ARHB and NEMU methods were superior to the NEX method and again there was no statistical difference in the findings between the 2 methods.16 The ARHB method requires accurate length measurement and use of complex mathematical calculations, which may limit feasibility.16 Nursing staff would also need formal education and practice to use this method for enteral tube placement. Evidence supporting the NEMU method has been available for the past 30 years, yet many neonatal units continue to use the NEX method.
A combination of methods will provide the nurse with information needed to verify placement. Studies support that a gastric aspirate pH of 5 or less indicates correct tube placement in the stomach 92% of the time.14,21 The inability to aspirate secretions may indicate that the tube is not in the stomach. In this case, the tube should be removed and replaced. Examining the color of aspirate may help rule out intestinal placement. Once initial tube placement has been verified, marking the tube at the lip or nares in conjunction with other methods will allow the nurse to ascertain if the tube subsequently dislodges.1,11 Assessing the patient's reaction to the insertion of the tube is an additional assessment method. Coughing, gagging, and a brief drop in heart rate are common during tube placement; however, these symptoms usually resolve quickly. When spontaneous recovery does not occur, the tube should be removed and reinserted. Patients with neurologic impairment that prevents protective cough and gag reflexes, or patients receiving medications such as heavy sedation or paralytics, require radiographs to verify correct initial placement. Verification of tube placement should occur prior to each feed. A radiograph should be obtained at any point during the placement verification process if there is a concern regarding enteral tube location. Auscultation is no longer an acceptable method for determining placement and should not be used, as it is not possible to determine that the sound of air insufflated into the tube is originating from the stomach.
Verifying correct placement of an enteral tube is a complex process. Radiography is the criterion standard but is not a practical method for verifying placement prior to each tube use. As no other single verification method provides the accuracy of a radiograph, combining 2 or more methods may provide nurses with the information they need to feel confident that an enteral tube is in the correct location.1,11,31 Use of a decision tool, such as an algorithm (see Figure 2), may provide a standardized, evidence-based approach for safe and effective use of enteral tubes in neonates and young children. Once the recommendations presented here are implemented into daily practice by interdisciplinary care teams, it is important to use quality improvement methods to frequently monitor the unit's success. Unit-specific data collection allows measurement of how the unit is doing in following best practice. Deviation from the standard will be evident in the data and will enable the unit to anticipate any patient safety issues that may occur or provide ongoing education that may be needed.
| Figure 2. Algorithm for performing and verifying optimal placement of gastric enteral tubes. |
CONCLUSION
Placement of enteral tubes is a daily practice in neonatal and pediatric units, yet development and implementation of an evidence-based national consensus for placement and location verification of these tubes have not occurred. Accurate placement is critical to the safe and effective use of enteral tubes. A tube that is placed too high (in the esophagus or lungs), or too deep (at or beyond the pylorus), can have significant detrimental effects on the patient. Enteral tubes should be placed using the NEMU method. Obtaining a radiograph is the ideal method for verifying placement, but this method is not practical on a routine basis. Aspirating gastric content to examine color and test pH, along with verifying nonmigration of the tube by assessing markings, is a combination that will assist the nurse in making an informed verification of enteral tube placement and ensure safe, effective practice.
References
1. Longo A. Best evidence: nasogastric tube placement verification. J Pediatr Nurs. 2011;26(4):373-376. [Context Link]
2. Peter S, Gill F. Development of a clinical practice guideline for testing nasogastric tube placement. J Spec Pediatr Nurs. 2009;14(1):3-11. [Context Link]
3. Irving SY; NOVEL Project Work Group. The NOVEL Project: what do we know about enteral tubes in pediatric patients? Paper presented at: Nursing of Children Network (NCN) 11th Annual Regional Nursing Conference; October 20, 2014; Wilmington, DE. [Context Link]
4. Ellett MLC. What is known about methods of correctly placing gastric tubes in adults and children. Gastroenterol Nurs. 2004;27(6):253-259; quiz 260-261. [Context Link]
5. Ellett MLC, Cohen MD, Perkins SM, Smith CE, Lane KA, Austin JK. Predicting the insertion length for gastric tube placement in neonates. J Obstet Gynecol Neonatal Nurs. 2011;40(4):412-421. [Context Link]
6. Quandt D, Schraner T, Bucher H, Mieth RA. Malposition of feeding tubes in neonates: is it an issue? J Pediatr Gastroenterol Nutr. 2009;48(5):608-611. [Context Link]
7. de Boer J, Smit B, Mainous R. Nasogastric tube position and intragastric air collection in a neonatal intensive care population. Adv Neonatal Care. 2009;9(6):293-298. [Context Link]
8. Filippi L, Pezzati M, Poggi C. Use of polyvinyl feeding tubes and iatrogenic pharyngo-oesophageal perforation in very low-birth-weight infants. Acta Paediatr. 2005;94(12):1825-1828. [Context Link]
9. Gluer S, Schmidt AI, Jesch NK, Ure BM. Laparoscopic repair of neonatal gastric perforation. J Pediatr Surg. 2006;41(1):e57-e58. [Context Link]
10. Newhouse RP, Dearholt SL, Poe SS, Pugh LC, White KM. Johns Hopkins Nursing Evidence-Based Practice Model and Guidelines. Indianapolis, IN: Sigma Theta Tau International Honor Society of Nursing; 2007. [Context Link]
11. American Association of Critical-Care Nurses. AACN Practice Alert: Verification of Feeding Tube Placement (Blindly Inserted). Aliso Viejo, CA: American Association of Critical-Care Nurses; 2009. [Context Link]
12. Beckstrand J, Ellett ML, McDaniel A. Predicting internal distance to the stomach for positioning nasogastric and orogastric feeding tubes in children. J Adv Nurs. 2007;59(3):274-289. [Context Link]
13. Burns SM, Carpenter R, Blevins C, et al. Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector. Am J Crit Care. 2006;15(2):188-195. [Context Link]
14. Ellett MLC, Croffie JM, Cohen MD, Perkins SM. Gastric tube placement in young children. Clin Nurs Res. 2005;14(3):238-252. [Context Link]
15. Ellet MLC, Woodruff KA, Stewart DL. The use of carbon dioxide monitoring to determine orogastric tube placement in premature infants. Gastroenterol Nurs. 2007;30(6):414-417. [Context Link]
16. Ellett MLC, Cohen MD, Perkins SM, Croffie JB, Lane KA, Austin JK. Comparing methods of determining insertion length for placing gastric tubes in children 1 month to 17 years of age. J Spec Pediatr Nurs. 2012;17(1):19-32. [Context Link]
17. Ellett MLC, Cohen MD, Croffie JM, Lane KA, Austin JK, Perkins SM. Comparing bedside methods of determining placement of gastric tubes in children. J Spec Pediatr Nurs. 2014;19(1):68-79. [Context Link]
18. Freeman D, Saxton V, Holberton J. A weight-based formula for the estimation of gastric tube insertion length in newborns. Adv Neonatal Care. 2012;12(3):179-182. [Context Link]
19. Gallaher KJ, Cashwell S, Hall V, Lowe W, Ciszek T. Orogastric tube insertion length in very low-birth-weight infants. J Perinatol. 1993;13(2):128-131. [Context Link]
20. Gilbert RT, Burns SM. Increasing the safety of blind gastric tube placement in pediatric patients: the design and testing of a procedure using a carbon dioxide detection device. J Pediatr Nurs. 2012;27(5):528-532. [Context Link]
21. Gilbertson HR, Rodgers EJ, Ukoumunne OC. Determination of a practical pH cutoff level for reliable confirmation of nasogastric tube placement. JPEN J Parenter Enteral Nutr. 2011;35(4):540-544. [Context Link]
22. Irving S, Lyman B, Northington L, Bartlett J, Kemper C; NOVEL Project Work Group. Nasogastric tube placement and verification in children: review of the current literature. Crit Care Nurs. 2014;34(3):67-78. [Context Link]
23. Metheny NA, Eikov R, Rountree V, Lengettie E. Indicators of feeding tube placement in neonates. Nutr Clin Pract. 1999;14:307-314. [Context Link]
24. Metheny N, Meert KL. Monitoring feeding tube placement. Nutr Clin Pract. 2004;19(5):487-495. [Context Link]
25. National Association of Children's Hospitals, ECRI Institute. Blind Pediatric NG Tube Placements Continue to Cause Harm. Overland Park, KS: Child Health Patient Safety Organization Inc; 2012. [Context Link]
26. Reducing the harm caused by misplaced naso and orogastric feeding tubes in babies under the care of neonatal units. National Patient Safety Agency Web site. http://www.nrls.npsa.nhs.uk/resources/type/alerts. Published September 18, 2005. Accessed June 22, 2014. [Context Link]
27. Reducing the harm caused by misplaced nasogastric feeding tubes in adults, children and infants. National Patient Safety Agency Web site. http://www.npsa.nhs.uk/corporate/news/reducing-the-harm-caused-by-misplaced-naso. Published March 21, 2011. Accessed June 22, 2014. [Context Link]
28. National Guideline Clearinghouse. Best evidence statement (BESt). Confirmation of nasogastric/orogastric tube (NGT/OGT) placement. http://www.guideline.gov/content.aspx?id=35117&search=nasogastric. Published August 22, 2011. Accessed June 13, 2014. [Context Link]
29. Nyqvist KH, Sorell A, Ewald U. Litmus tests for verification of feeding tube location in infants: evaluation of their clinical use. J Clin Nurs. 2005;14(4):486-495. [Context Link]
30. Tedeschi L, Altimer L, Warner B. Improving the accuracy of indwelling gastric feeding tube placement in the neonatal population. Neonatal Intensive Care. 2004;16(1);16-18. [Context Link]
31. Wallace T, Steward D. Gastric tube use and care in the NICU. Newborn Infant Nurs Rev. 2014;14:103-108. [Context Link]
32. Westhus N. Methods to test feeding tube placement in children. MCN. 2004;29(5):282-289. [Context Link]
33. Kattwinkel J, Bloom RS, American Academy of Pediatrics, American Heart Association. Neonatal Resuscitation Textbook. 6th Editioned. Dallas, TX: American Academy of Pediatrics; 2011. [Context Link]
34. Ikuta LM, Beauman SS. Policies, Procedures and Competencies for Neonatal Nursing. Glenview, IL: National Association of Neonatal Nurses; 2011. [Context Link]
35. Metheny NA, Stewart BJ, Mills AC. Blind insertion of feeding tubes in intensive care units: a national survey. Am J Crit Care. 2012;21(5):352-360. [Context Link]
36. Morriss FH, Brewer ED, Spedale SB, et al. Relationship of human milk pH during course of lactation to concentrations of citrate and fatty acids. Pediatrics. 1986;78(3):458-464. [Context Link]
The CE test for this article is available online only. Log onto the journal website, http://www.JPNONline.com, or to http://www.NursingCenter.com/CE/JPN to access the test. For more than 38 additional continuing education articles related to perinatal and neonatal nursing, go to http://NursingCenter.com\CE.
children; enteral feeding; feeding tube; nasogastric tube; neonates